GateTel Sole distributors
|
Software updates: Previous Version Information (Format 3) SMS Alert 1 10.3 - 20160226 - Reset/Recovery protection improved. 10.4 - 20160505 - Return status updated 10.5 - 20160617 - Low Voltage delay 1234 13 fixed 10.6 - 20160630 - Roboguard siren check speed increased 10.7 - 20160725 - Miss Call reset to trigger relay fixed 10.8 - 20170614 - Startup delay and more time between SMSes added 10.9 - 20170417 - 1234 45 added to switch off return SMS for M2M applications 11.1 - 20180128 - Bug: Miss call input 1 to user B fixed 11.2 - 20180215 - Relay B and C added in software 11.2a-20181122 - Software stability improved - especially for miss call features, e.g. miss call to open gate. 11.3 - 20180512 - Storing of international numbers in EEPROM corrected/improved 11.4 - 20190812 - Change to newer processor. Code streamlined. Stability add on when triggering inputs N.A - 20220931 - Random Arm/Disarm SMSes messages sent/received - fixed N/A - 20230315 - Electric Fence/Pump on/off switching problems
SMS Alert 9 10.5 - 20160711 - 1234 14 added to allow Panic only to last 5 users only 1234 15 to turn on/off Power Loss restore input 3 added 1234 16 to turn on/off longer delay on input 9 for Low battery applications 1234 MCODE added to separate security on functions. 10.6 - 20170429 - Bug fixed on MCODE. Relay click on reset fixed 10.7 - 20170829 - Startup delay and more time between SMSes added 10.8 - 20170831 - Setting added to reset relays when SMS Alert is re-powerd. 10.9 - 20170831 - Bug fixed where more than 8 users causes a problem where not all 9 or10 users receive SMSes - Empty user positions now skipped - less delay between trigger - 1234 20 added to allow Burglary only to last 5 users only - 1234 21 added to allow all SMSes to all 10 users - 20180128 - Bug: Miss call input 1 to user B - fixed 11.0 - 20180901 - Input 8 Gate open remind and repeat function added - All inputs re-namable - All inputs single or dual state selectable - All inputs can be enabled or disabled. - Burglary and Panic input selectable to users 1-5 or 1-10 11.0a-20181122 - Software stability improved - especially for miss call features, e.g. miss call to open gate. 11.0b-20190603 - Attempt to solve garbage characters or EEPROM corruption caused by Vodacom SIM cards 11.c - 20190725 - Code streamlined 11.1 - 20181113 - 40 user SMS Alert 9 - on request 11.4 - 20190821 - Change to newer processor. 11.5 - 20190913 - Stability upgrade. 11.6 - 20191021 - Re-addition of previous code. MTN sim cards cause the unit to restart when loading numbers and therefore no return SMS is received. Use 1234 r to check loaded users. 11.7 - 20201205 - Bug on Key input fixed 11.8 - 20210315 - Stability ad on - memory related 11.9 - 20210611 - Stability ad on - triggering of inputs related 12.0 - 20210707 - Opening of gate (relay) missed call fixes for 1234 06 and 1234 25. All 10 users now allowed vs only user B before 12.2 - 2021 10 - Protection added for funny Scrambled SMS text, also resulting in no access/response to unit via security code 1234 (default) - Note: We can remotely restore/fix access to the unit by supplying your sim card number 12.2 - 2021 10 - CUSTOM : Pivot monitoring feature. Unit will SMS 1-"Staan"/"Stand", 2-"Klaar"/"Finished", 3-"Krag aan"/"Power On", 4-"Water af"/"Water off" and 5-"Water Aan"/"Water On". In the event that 1, 3, and 5 are all active . implying a problem, the device will also miss call the user. N.A - 20220931 - Random Arm/Disarm SMSes messages sent/received - fixed N/A - 20230315 - Electric Fence/Pump on/off switching problems
SMS Alert 9 Alarm Plus (SA9+) 10.5 - 20150828 - 1234 10 Night LED Power loss motion added 10.6 - 20150923 - Code compiled with debug mode off 10.7 - 20150930 - 1234 11 added to turn on/off input 3 (Power Loss / Restore) 10.8 - 20160510 - 1234 12 added to pulse pepper gas when Panic (input 9) is triggered 10.9 - 20160530 - 1234 13 added for camera flash 11.0 - 20160606 - 1234 2x added to change inputs between NC and NO 11.1 - 20160328 - 1234 14 added to enable relay A to latch. Relay E and F selectable 11.2 - 20170124 - 1234 3x added to enable/disable zones. 1234 t changed to also exit test mode 11.3 - 20170602 - Startup delay and more time between SMSes added (current Release) 11.4 - 20190801 - Auto arm function added - use 1234 16 to enable this feature. This will auto arm the system after 1 hour - (pls revert back to V11.3) 11.6 - 20190826 - Bug fix for version 11.4 - pending, revert back to V11.3 11.7 - 20200306 - 10s delay, and Siren warning Setting added if automatic pepper-spray function is used vs the current immediate release of gas. This allow time to disarm the system in case of unnecessary alarm activation. - Input 9 can be set between Panic and Battery Low - System will disarm if main user is removed (safety feature) - Siren on time can be increase to 5 min. 11.7 - 20200306 - 10s delay, and Siren warning Setting added if automatic pepper-spray function is used vs the current immediate release of gas. This allow time to disarm the system in case of 11.8 - Emergency nigh light functional add-ons 11.9 - Emergency nigh light functional add-ons 12.0 - 20200622 - 24 hour zones can be selected/enabled. 12.1 - 20200706 - Panic Priority user Added and Relay B for external Radio trigger 12.2 - 20200801 - Cosmetic fix for 1234 b not responding 12.3 - 20200826 - Low voltage notification fixed, stability added 12.4 - 20200908 - Relay B for external Radio bug fix, and 1234 ap lock on startup fixed 12.5 - 20210604 - LED strobe feature added. 12.6 - 20210604 - Accidental spray feature added 12.7 - 20210815 - Miss Call outgoing for Zone 1 fixed. 12.8 - 2021 12 - Output relay A and B SMS confirmation added (pulse) )to prevent delayed switching when SMSes are delayed on the network. - Recognised miss call feature added (pulse) for all users to e.g. open a gate selectable via Relay A or B - Latched relay miss call added for Relay A and B versus the normal Pulse - Examples of use : Pivot switching on/off via miss call, and auto answer listen in to verify pump is running via microphone fitted on SMS Alert N.A - 20220931 - Random Arm/Disarm SMSes messages sent/received - fixed N/A - 20230315 - Electric Fence/Pump on/off switching problems
Intercom 20161218 - upgraded to 6 buttons - Long international numbers can be dialed. - Sound quality improved
SMS Alert 15 20170122 - 1234 CODE function added where the code sometimes get scrambled 20180418 - Auto reply on network spam SMSes removed - reset problem fixed. 20180531 - Key input now power loss restore input
SMS Alert 15 Alarm plus 20150612 - Panic split users added 20150831 - Bypass zones 10-14 via input 15 - fix to remote arm disarm 20160703 - Bat low added. Zones on off function added 20170307 - International code setting added as 1234 46
SMS Temperature Alert (GSM) 20160606 - 1234 CODE re-added 20170816 - Power loss restore indication added on 1234 r 20170925 - Alarm output and reset button added 20180613 - Added report version 20180629 - Faster temperature scanning added. Stability/reliability upgrade 20180824 - Single digit problem fixed for temperature below 10 degrees 20180914 - Repeat of temperature OK during long wires or EMI interferences improved to minimal or none at all 20180716 - Humidity added 20180715 - Wireless remote sensors option added 20181008 - "Power ON" missing especially with systems using a 1+ sensors (Temp 2, Temp 3 etc)
9.4 - 20180224 - Humidity problem fixed Software stability improved 9.5 - 20180224 - Hour Counter 1234 07 added 9.6 - 20190424 - 1234 07 bug fixed - 1234 r1 and 1234 r2 added for checking more than 4 temperature 9.7 - 20190614 - 24h system check bug fixed - When enabled, the return message was only sent to user T 9.8 - 20190623 - 24h hour cosmetic return setting message fixed. 1234 r fixed - was returning message to default user (B) and not client
SMS Temperature Alert (Controller) 20181008 - Faster update of Temperature on LCD 1.1 - 20160630 - Improved double check of temperature readings. 1.2 - 20160702 - Faster menus added - Off display added. 1.4 - 20170109 - Problem with new batch of LCDs fixed - High and Low limits added 1.5 - 20180611 - LCD off function in menu removed - code spacing changed 1.6 - 20180629 - Some delays changed 1.7 - 20180701 - Humidity added 1.9 - 20180906 - ShowH added in menu 2.0 - 20180914 - Stability improved - auto revover added 2.1 - 20180710 - Faster temperature readings 2.2. - 20181123 - Stability improved - Relay added BypassOFF added 2.3 - 20181127 - Cosmetic changes to Humidity Character on LCD fixed - RF module control improved to prevent freezing of RF module 2.4 - 20200505 - High and Low Temperature "Lock" feature added to buttons in case they are pressed
Charger board (hardware) 20180101 - Threshold auto cutoff parameters changed.
20170711 ver 1.3 - Ad-hoc improvements - stability and robustness - Airtime request fixed, but limited.
SMS Panic Alert 20180723 - Microphone enabled only for registered users. Test button added
GSM module update (top plug in PCB) 20181018 - VER 4.1 MTN voucher load fixed. Default USSD code changed from 141 to 136 20210815 - Stability update. Corruption of SMS text or reset issues. An existing DOT command can be used for previous versions to fix this. This will disable the DOT load method of cellphone numbers, and only the older methods will work. Contact us in this regard.
General Trouble Shooting (Fault Finding) 20191121 Q: Units with GSM module version 4.4 does not report airtime or stops responding thereafter. A: Wait for 5 min or longer for unit to time-out and to restart or manually re-power. Retry sending a general request 1234 r. If the unit replies then send 1234 WC only once. (The wait call bit is set and should not be set - this affects the airtime function)
Previous Version Information (Format 2)
Previous Version Information (Format 1)
*Note : During production and packaging 3 test cycles are completed. We aim to perform extensive testing as far as possible. However, upgrades cannot be done by downloading new software from the internet. In most cases you can send us your chip and we will reprogram it with the latest updates. The price (minimal) of an upgrade depends on the extend of the upgrade.
|
|